Previous Release History (for historic
reference only)
Please ALWAYS use the Current
Release and the latest patch (if any) .
Below
here
is only relevant to software archaeologists and people who don't want to
use the current release. If you don't then please tell me why?
Previous release version, files and MD5 checksums are as detailed in the
tables below:
The current release version, files, MD5 and SHA256 checksums are as
detailed in the table below:
Version
|
File
|
MD5
/ SHA2 256 Checksums |
Date
|
V3.9.0.0 |
Scan125_V3900.zip |
7763D42BB83245C46979152E8CA9EB50
6CD04A62F92DB14CA3E1D6F64A429A5859786C40524320C621CF37DE38EBFBFB
VirusTotal |
21 April 2025 |
V3.9.0.0 |
Scan125.exe |
94974A21FC9646F711D2506D2164DA11
D6B8455924AD9A2516F2529978EFEA009504C8318AF11C7D98078940FCCAE1C3
VirusTotal |
21 April 2025 |
NEW in V3.9.0.0
- Add - Scan Banks Channel Select Range Selection using Shift Key and
Mouse Click
- Add - Improved / Change Scan Banks Channel Selection Code
- Add - Additional BASS Error debug information
Fixes in V3.9.0.0
- Fix - Scan Banks View/Edit - Channel(s) Move deletes data when there
is Source & Destination overlap
- Fix - Setting Datagrid Readonly causes Select delay and count issues
- Fix - Ensure BASS errors are logged in runlog file
Known Issues in V3.9.0.0
Custom Load Bank X to Bank Y is not working correctly. Appears to
have always been broken!
Version
|
File
|
MD5
/ SHA2 256 Checksums |
Date
|
V3.8.0.0 |
Scan125_V3800.zip |
E8570923A98C4E427C96D057F14B76A7
71A71963F57F379B01B3EDBE56A3B4A1FE78C4FBD62853FF6DE5B094932E07C0
VirusTotal |
20 October 2024 |
V3.8.0.0 |
Scan125.exe |
D44C041384DA14BB7F2CDE536061B6D9
7E9A33DBFF810707D004EFB811F54DB5998F93EC5E3F6A567C251A66CFED5648
VirusTotal |
20 October 2024 |
NEW in V3.8.0.0
- Add - Changing of Display Lines 1 to 6 Back Colour - Big & Ribbon
displays Inherit
- Add - Custom File Load - Load Bank x from file to Bank y
Fixes in V3.8.0.0
- Fix - Weather Alert WX not showing on Display Line 6 for
BC125AT
Known Issues in V3.8.0.0
None
Version
|
File
|
MD5
/ SHA2 256 Checksums |
Date
|
V3.7.0.0 |
Scan125_V3700.zip |
06FE0C6B16CA2F65541CCD2CF86F0123
351CB56E00B1D57F3AAEDFC57642C96A7CF406407339C85842E7475F2ECD7CC3
VirusTotal |
22 December 2023 |
V3.7.0.0 |
Scan125.exe |
FFAD6AE3920218AF4CD19BA66DAF7BEA
77FD1AEABB951FA04ADB05C382A55D674D8BF3B353A507EFAC1BBD5336C82C1B
VirusTotal |
22 December 2023 |
NEW in V3.7.0.0
- Add - Mono/Stereo Recording Option
- Add - 8/16/32 Bit Depth Recording
- Add - Auto restart after COM error
- Add - Recording.txt information file
Fixes in V3.7.0.0
- Fix - COM [R] button not finding scanner if scanner is still connected
OK
- Fix - Fix scan banks channel select checkbox not being unchecked after
delete
Known Issues in V3.7.0.0
The User Manual does not contain information about the Recording.txt file.
When recording this file contains the path\audio_file_name,
sample_frequency,sample_channels,sample_bits information of the
audio file being recorded. This file is for use by any other program.
Version
|
File
|
MD5
/ SHA2 256 Checksums |
Date
|
V3.6.0.0 |
Scan125_V3600.zip |
9D242D1ED6A1E439094851F2E17C319A
6060DAB863551116B9407BD81C066356D74104F3AB9CAE1FE096F2310297D42A
VirusTotal |
01 August 2023 |
V3.6.0.0 |
Scan125.exe |
63FD3250263E1E43F25E2947EAF06839
FFC32C601E2F982AB05B27FD4670C27F5421FFDE5DAAE46135E70CFE34CF37AB
VirusTotal |
01 August 2023 |
NEW in V3.6.0.0
- Add - Current Channel.txt file - Proscan "Current Channel.txt" format
file for use in RRUK Linker program
Fixes in V3.6.0.0
- Fix - Fix Speak key D should say Speak Disabled And Not Enabled
- Fix - Display routine Case statement does not allow for Key AND Bat at
same time
Known Issues in V3.6.0.0
None
Version
|
File
|
MD5
/ SHA256 Checksums |
Date
|
V3.5.0.0 |
Scan125_V3500.zip |
6A698C832F2C67041F2E5E756CB57BFD
4EA3A73793EA9B7E865B0F9F8CC6F70890C94277A5F9678A9E6CAB0D20FA341D
VirusTotal |
06 February 2023 |
V3.5.0.0 |
Scan125.exe |
1C65A0F49E1BBA3EBD8631E423BDE277
EE795A468ED69A251B9209B44053D188F3CAF63D52F8062175940359C66DF73F
VirusTotal |
06 February 2023 |
NEW in V3.5.0.0
- Add - Voice Speaking for Blind users - Initial basic items
- Add - OS 32/64 bit info and program build flag settings to ini file
- Add - Auto pause Delay Time to audio recording
- Add - Scan and Search Bank tag names to Checkbox Titles
- Change - COM Port device settings to support some FDTI chip / driver
combinations (drop setting of DTR & CTS)
- Change - COM Port Box back colour to light green for legibility
Fixes in V3.5.0.0
- Fix - Stop exception on .TRIM if current_channel / other variables is
Nothing/Null
- Fix - Attempt to read a full scanner data file for an incorrect model
clears program's channel data. Force a read of scanner again
- Fix - missing ScanChannels form disable/enable when changing Select
checkbox
- Fix - ScanChannels Update_Data_Table(chan_no) - do not change Select
status to False - not rquired - upsets Scan75 SR30C support
- Fix - Option CBUS frequencies not being checked
Known Issues in V3.5.0.0
None
NOTE! This release is an update and is functionally identical to
V3.4.0.0 - 18 June 2021. The is required due to an Exception when
Searching which is due to a RECENT Windows (post 18Jun21) dot
NET/Quality Update now trapping a pre existing issue with VB .TRIM
function.
Version
|
File
|
MD5
/ SHA256 Checksums |
Date
|
V3.4.1.0 |
Scan125_V3410.zip |
9FCDF7ED7CF5521F831BBBF98326AFBA
05CA06133926E30D96A95BF1D280A69C22F3B2309920DA62799B41CE49D359B7
VirusTotal |
01 July 2021 |
V3.4.1.0 |
Scan125.exe |
C1FB8A5542414941F364D85155D39A8F
33785468D2B99B9F467C75B5AF92EBBD9A15E6579B5AB6C6CD5F264C304A4D9D
VirusTotal |
01 July 2021 |
NEW in V3.4.1.0
- Add - WAV Recording To Sub Directories
- Add - Improved Bank Sort - Blank tag names and frequencies of
0000.0000 now put last
- Add - Add/Use/Replace programs internal Recording Play with system's
default player - also fixes mciSendString error with long file name
- Add - Use style for HTML formatting - Add Font Size and Back/Fore
Colour Options
- Add - Add Power OFF confirmation dialogue
- Add - Write status time average value calculated to ini file
- Add - Allow optional READLINE / READEVENT non sticky setting in ini
file - default still READEVENT
- Add - Add Polling Setting Status Label
- Add - Write Serial Port/COM error info the Runlog file
- Add - Skip and Log corrupt STS status response and wait for next
- Add - Add Port List, Port Used and Model to Runlog
- Add - Audio file name to BASS error Message Box
- Add - Scanner model and firmware versions to ini file
- Add - Size check and delete of Runlog file
Fixes in V3.4.1.0
- Fix - Alternate date/time settings causing audio recording to fail
with BASS Write error
- Fix - T/LO flag not being set when status decoded + correct scanning
detection in L/O and TL/O routines
- Fix - Status field count error when Viewing Close Call Bank.
Reception Status counting fields incorrectly
- Fix - Undo blocking of L/O and TL/O while scanning is active
- Fix - Incorrect date DAY format - should be 0d/mm/yy and not just
d/mm/yy - causes BASS recording error
- Fix - Changing Custom Search frequencies are not be changed in Search
Bank tool tips
- Fix - Bass.BASS_RecordGetInput(0, vbNull) - Invalid Parameter
occasionally thrown - fold to OTHER and do not error
- Fix - Record Stop not re-enabling Options sample rate change combobox
- Fix - Scanner in HOLD should not start scanning again on program close
Known Issues in V3.4.1.0 None
Version
|
File
|
MD5
Checksum
|
Date
|
V3.4.0.0 |
Scan125_V3400.zip |
7F27FD87A6AE78EAC1AEA1D613EB632D |
18 June 2021 |
V3.4.0.0 |
Scan125.exe
|
D2D9E37F5202E53E44FE8CE8FEF6D7C7
|
18 June 2021 |
NEW in V3.4.0.0
- Add - WAV Recording To Sub Directories
- Add - Improved Bank Sort - Blank tag names and frequencies of
0000.0000 now put last
- Add - Add/Use/Replace programs internal Recording Play with system's
default player - also fixes mciSendString error with long file name
- Add - Use style for HTML formatting - Add Font Size and Back/Fore
Colour Options
- Add - Add Power OFF confirmation dialogue
- Add - Write status time average value calculated to ini file
- Add - Allow optional READLINE / READEVENT non sticky setting in ini
file - default still READEVENT
- Add - Add Polling Setting Status Label
- Add - Write Serial Port/COM error info the Runlog file
- Add - Skip and Log corrupt STS status response and wait for next
- Add - Add Port List, Port Used and Model to Runlog
- Add - Audio file name to BASS error Message Box
- Add - Scanner model and firmware versions to ini file
- Add - Size check and delete of Runlog file
Fixes in V3.4.0.0
- Fix - Alternate date/time settings causing audio recording to fail
with BASS Write error
- Fix - T/LO flag not being set when status decoded + correct scanning
detection in L/O and TL/O routines
- Fix - Status field count error when Viewing Close Call Bank.
Reception Status counting fields incorrectly
- Fix - Undo blocking of L/O and TL/O while scanning is active
- Fix - Incorrect date DAY format - should be 0d/mm/yy and not just
d/mm/yy - causes BASS recording error
- Fix - Changing Custom Search frequencies are not be changed in Search
Bank tool tips
- Fix - Bass.BASS_RecordGetInput(0, vbNull) - Invalid Parameter
occasionally thrown - fold to OTHER and do not error
- Fix - Record Stop not re-enabling Options sample rate change combobox
- Fix - Scanner in HOLD should not start scanning again on program close
Known Issues in V3.4.0.0
Version
|
File
|
MD5
Checksum
|
Date
|
V3.3.0.0 |
Scan125_V3300.zip |
0D15C23CF278ABFC9CB2B7787AE930C1
|
10 October 2020 |
V3.3.0.0 |
Scan125.exe
|
85895C96D317FBC19F6F2C6BD5AD95D8
|
10 October 2020 |
NEW in V3.3.0.0
- Add - Add HTML Frequency Monitoring File (useful for audio streaming
information and website information)
- Add - Error message trap for when scanner returns more status data
fields then expected (stops hard errors)
Modifications in V3.3.0.0
Fixes in V3.3.0.0
- Fix - Notepad data not being written in release V3.2.0.0 only
- Fix - Fix _waveWriter.dispose exception if recording not done (only
visible in Windows Event logs)
Known Issues in V3.3.0.0 Alternate
date/time settings causing audio recording to fail with BASS Write error
Version
|
File
|
MD5
Checksum
|
Date
|
V3.2.0.0 |
Scan125_V3200.zip |
912BC55C11576134F56235FA76978CAB
|
22 August 2020 |
V3.2.0.0 |
Scan125.exe
|
EAC448A96E3364AAAA59BD80546AFC8B |
22 August 2020 |
NEW in V3.2.0.0
- Add - Reset log_data_flag on program exit to stop excessive logging
- Add - Channel Name Tag to duplicate entry / store warnings
- Add - New reworked and simplify Serial Code
- Add - Serial Port Asynchronous data reception
- Add - Test for scanner on last used port first - speed up detection
- Add - Flag driven forced log entry for SendCommand retry events
setting
- Add - Handle when scanner does not always respond and drops commands
or replies out of sequence
Modifications in V3.2.0.0
- Mod - Move WAV File delete process from program start up to program
shut down
- Mod - Change method of getting channel name tag for recording file
name
- Mod - Expand and change information in recording file name
Fixes in V3.2.0.0
- Fix - Do not have STORE button disabled when doing direct frequency
tuning input
- Fix - Rare/very occasional BASS Channel Stop Error (while recording),
Invalid handle BASS Error Code:5
- Fix - DataGridView tables not AutoSizeColumns filling to full width.
No code change - DataGridView property change
- Fix - Missing channel tag name in generated Butel RSF file
Known Issues in V3.2.0.0 Notepad
file scan125-notepad.txt is not being written on program exit. If this
is a problem for you then please download this replacement Scan125.exe
file. NOTE! This replacement file will not work on it's own and has to
be used to update the full V3.2.0.0 release.
Version
|
File
|
MD5
Checksum
|
Date
|
V3.1.0.0 |
Scan125_V3100.zip |
76E8C6FC51A3DE6A6646CD1620EBEBA7
|
22 June 2020
|
V3.1.0.0 |
Scan125.exe
|
2A9B7F09A7EE5A3655446783C91E533D
|
22 June 2020 |
NEW in V3.1.0.0
- Add - Recording input sound source selection
- Add - Menu "Support" menu item
Modifications in V3.1.0.0
- Mod - Stop "Bearcat" label flashing
Fixes in V3.1.0.0
Known Issues in V3.1.0.0
Version
|
File
|
MD5
Checksum
|
Date
|
V3.0.0.0 |
Scan125_V3000.zip |
F109812839F7D5070957EF7D818D27EB
Scan125_V3000.zip
|
19 March 2020 |
V3.0.0.0 |
Scan125.exe
|
B3D6B2BCF95373A017FCA3363A9192AD
Scan125.exe |
19 March 2020 |
NEW in V3.0.0.0
- Add - Frequency Log view form - access from the Notepad/Autosave form
or from it's View/Edit button
- Add - Frequency Log view form auto refresh
Fixes in V3.0.0.0
- Fix - null scan type filed in frequency log - Default to [None]
- Fix - channel tag names can contain characters that are invalid for
audio file names causing BASS error
- Fix - Autosaved Frequencies Table not sorting correctly when count
exceeds 999 - increase format from 000 to 00000
- Fix - Extraneous tag names name tags after channel delete followed by
bank sort and commit
Known Issues in V3.0.0.0
Version
|
File
|
MD5
Checksum
|
Date
|
V2.9.0.0 |
Scan125_V2900.zip |
980448AD944A9046D7FD3FF7C4EC52F5
Scan125_V2900.zip
|
14 February 2020
|
V2.9.0.0 |
Scan125.exe
|
2607C9442FA3A9D7E75A165713A13140
Scan125.exe
|
14 February 2020 |
NEW in V2.9.0.0
- Add - Bank Channel Sort and Save to scanner
- Add - Frequency ranges to Custom Search check box controls mouse over
tool tips
- Add - Scan Banks channel name and number lookup for Search and
Services scan hits
- Add - Information message when recording fails to initialise possibly
due to no audio cable between scanner and PC's sound card
- Add - Message "Channel Store/Copy/Move Pending - Please Select the
Channel Prefix Field on the far left of the data grid."
Fixes in V2.9.0.0
- Fix - Band Plan BPL command on BC125AT only supported in firmware
V1.03.01 and above
Known Issues in V2.9.0.0
- Channel Tag Names can contain characters invalid for audio file
recording files
Version
|
File
|
MD5
Checksum
|
Date
|
V2.8.0.0 |
Scan125_V2800.zip |
37BFDAE4764377816FD040F57A44DD9E
Scan125_V2800.zip
|
21 November 2019
|
V2.8.0.0 |
Scan125.exe
|
57703C718A4D23E4A2EB6526DA6A6A79
Scan125.exe |
21 November 2019 |
NEW in V2.8.0.0
- Add - Support for 32 bit OS - handle two different bass.dll files
- Add - Information message when recording fails due to Windows Privacy
Microphone access turned off
- Add - Two tries at identifying scanner (for troublesome PCs)
- Add - Print to relevant forms and remove "Print Form" and associated
PowerPack DLL dependency
- Add - Improve Band Step & Modualtion menu walking speed and
reliability
- Add - Improve Close Call Bank menu walking speed and reliability
Fixes in V2.8.0.0
- Fix - Airband correction on unoffical .020 and .070 channels
- Fix - AE125H custom search model index exception
- Fix - MOD change can only be done when scanner not scanning
- Fix - Trapping of WndProc exception - (never seen by user - only when
running under VS)
- Fix - Repeated port [R] tries creates array bounds exception
- Fix - Close Call Only does not show "BND:" but displays last BNK, SRC
or SVC header
- Fix - Close Call Bank View Button should not be enabled in Close Call
Mode Only operation
Known Issues in V2.8.0.0
- Command BPL will fail due to
BC125AT's firmware not being at V1.03.01 or greater. UBC125XLT,
UBC126AT and AE125H models are not affected. If you get this error
then please upgrade your firmware to the latest level (BC125AT Firmware Update). Issue is resolved
in the next release. If you have this problem and are unable or
unwilling to update your BC125ATs firmware then please contact me for a
replacement EXE file.
Version
|
File
|
MD5
Checksum
|
Date
|
V2.7.0.0 |
Scan125_V2700.zip |
9E855B62BCC5B691F2CB1585D40ADC7B
Scan125_V2700.zip
|
20 April 2019
|
V2.7.0.0 |
Scan125.exe
|
49BF33F2E668D7931B2790994EAF4186
Scan125.exe
|
20 April 2019 |
NEW in V2.7.0.0
- Add - New Audio Recording system using BASS and BASS.NET sound library
functions (BASS.DLL)
- Add - Windows Version Information
- Add - .NET 4.5 now required (by BASS)
Fixes in V2.7.0.0
- Fix - Only audio noise is recorded on Windows 10 systems
Known Issues in V2.7.0.0
- If you are running on a 32 bit Windows OS version then you will get an
exception thrown by the included BASS based recording function. If
you encounter this (only one person has so far) then please contact me
and I will supply a replacement BASS.DLL file that will resolve this
issue.
- On Windows 10 when attempting to record you may get a BASS error code
of "BASS Error -_waveWriter - BASS Error Code 5". This is
almost certainly because in your privacy settings you have APP access to
microphone turned off. You need to change these settings
accordingly. Note there is an overall setting and a per
application setting.
Version
|
File
|
MD5
Checksum
|
Date
|
V2.6.0.0 |
Scan125_V2600.zip |
413F01156BE78DAB52516EDC095EDBA3
Scan125_V2600.zip
|
24 January 2019
|
V2.6.0.0 |
Scan125.exe
|
8B895A928922B8FA1EDBE9115927DDBC
Scan125.exe
|
24 January 2019 |
NEW in V2.6.0.0
- Add - Direct Frequency Tuning Of Scanner (tune like a more traditional
receiver)
Fixes in V2.6.0.0
- Fix - Tooltip Scan Bank 6 not working
- Fix - Tooltip Service Banks 8, 9, 0 repeat Service Bank 7 tooltip
- Fix - AE125H does not support NFM - fold to AUTO and let scanner
decide
- Fix - AE125H only supports up to level 14 / 2300mAh battery charge
setting
Known Issues in V2.6.0.0 Windows
10 users may find that when recording with Scan125 then only noise is
actually recorded
Version
|
File
|
MD5
Checksum
|
Date
|
V2.5.0.0 |
Scan125_V2500.zip |
0A2FA058D711246A5ABDAC64C0CC19B6
|
25 August 2018
|
V2.5.0.0 |
Scan125.exe
|
4C515623EA5D29A208433D8C579F3E51
|
25 August 2018 |
NEW in V2.5.0.0
- Add - Setting of Enable/Disable Bank Scan Buttons Tooltips to Relevant
Scan / Search / Services Values
- Add - Comments link to website form
- Add - Improve Up / Down direction determination - stops u/d flickering
in virtual display
- Remove - Registration Function / Requirement
Fixes in V2.5.0.0
- Fix - Modulation not being set correctly when using frequency prefixes
- e.g. CBUK10 was not setting FM rf mode
- Fix - Not every PC has the script type font for the "Bearcat" label -
changed to more generic system front
Known Issues in V2.5.0.0 Scan Drop
Bank Button 6 Tooltip Not Working (05Sep18) - fixed in next release
Version
|
File
|
MD5
Checksum
|
Date
|
V2.4.0.0 |
Scan125_V2400.zip |
0C619344F7FB6315D881735344FC3459
|
02 June 2018
|
V2.4.0.0 |
Scan125.exe
|
98CE190B61067B19C875B27239022C0E
|
02 June 2018 |
NEW in V2.4.0.0
- Add - Channel Fast Tune now jumps directly to channel instead of using
Quick Search and Hold where channel information is not shown
- Add - Display currently set LCL or GMT/UTC clock time with light green
background
Fixes in V2.4.0.0
- Fix - Modulation not being set correctly when using frequency prefixes
- e.g. CBUK10 was not setting FM rf mode
- Fix - Not every PC has the script type font for the "Bearcat" label -
changed to more generic system front
Known Issues in V2.4.0.0
Version
|
File
|
MD5
Checksum
|
Date
|
V2.3.0.0 |
Scan125_V2300.zip |
4B09D3E484B696CB4B6717E2EB7A7358
|
20 October 2017 |
V2.3.0.0 |
Scan125.exe
|
C2F355400F55ED86582E855815680A7E
|
20 October 2017 |
NEW in V2.3.0.0
- Add - Set default modulations for CB UK (fm) / EU (fm) / US (am) on
Scan Banks View/Edit
- Add - Port "R"efresh Button should also try to connect and read
reciever again
Fixes in V2.3.0.0
- Fix - Allow CBEUn and CBEU0n - same for CBUSn and CBUB0n
- Correct Out Of Band Error Message frequencies for BC125AT and UBC126AT
scanners
- Fix - Data exception when clearing Close Call Bank
(field_reception_data(8) set to 1 instead of field_reception_data(9) on
Nothing)
Known Issues in V2.3.0.0
- Modulation not being set correctly when using frequency prefixes -
e.g. CBUK10 was not setting FM rf mode (fixed in next release)
- Not every PC has the script type font for the "Bearcat" label -
changed to more generic system front (fixed in next release)
Version
|
File
|
MD5
Checksum
|
Date
|
V2.2.0.0 |
Scan125_V2200.zip |
DBECCFBB227F7C35C259A4B6A61190E0
Scan125_V2200.zip
|
07 July 2017
|
V2.2.0.0 |
Scan125.exe
|
C5DFF26BAD30463FD27FABA985064F04
Scan125.exe
|
07 July 2017 |
NEW in V2.2.0.0
- Add - Support for Albrecht AE125H scanner
- Add - Improve channel tag name and number logging accuracy
- Add - Auto/Dynamic Status Period option and remove FAST/SLOW speed
switching
Fixes in V2.2.0.0
- Fix - Fix Close Call Hit channels 501 to 510 being out of bounds
creating exception error
- Fix - Big and Ribbon Display volume controls not being correctly set
on form load
Known Issues in V2.2.0.0.
- Close Call Bank "Clear" causes data exception - fixed in next release
- Frequency prefix of "0n" causes exception. "9" is OK - fixed in next
release
- Out of band frequency message limits for BC125AT displayed with
UBC125XLT limit values - fixed in next release
Version
|
File
|
MD5
Checksum
|
Date
|
V2.1.0.0 |
Scan125_V2100.zip |
CE1A0B9F683A6823EB40C358291693AB
Scan125_V2100.zip
|
08 June 2017
|
V2.1.0.0 |
Scan125.exe
|
95FA88CDBC3FC19C29D51AA2D3C949FF
Scan125.exe
|
08 June 2017 |
NEW in V2.1.0.0
- Add - RSSI Signal strength meter sensitivity threshold adjustment
- Add - Add channel tag name and channel number to Notepad, Autosaved
and Frequency log file, including for custom and services scans
Fixes in V2.1.0.0
- Fix - Auto Saved Frequency hit counter sort - store as "00n" and not
"n". Allows better column sorting
Known Issues in V2.1.0.0. Close
Call Bank View - results in exception. Issue located and fixed in next
release. My appolgies for this regression. (19 June 2017)
Version
|
File
|
MD5
Checksum
|
Date
|
V2.0.0.0 |
Scan125_V2000.zip |
F4529368B9A59D2652C8F54C3DFC1DF4
Scan125_V2000.zip
|
15 April 2017
|
V2.0.0.0 |
Scan125.exe
|
787D96B83945068769DD0EEAC4E056E7
Scan125.exe
|
15 April 2017 |
NEW in V2.0.0.0
- Add - Dynamically Detect Scanner on COM port (Long awaited and my
Easter Bunny present)
- Add - Delete WAV files older than a given time period (options panel)
(user request)
- Del - Standalone running - not compatible with dynamic scanner
detection
Fixes in V2.0.0.0
- Fix - Band Plan, Step Size and Weather groups when disabled can not be
coloured
- Fix - Battery Voltage Conversion Exception when "" / null is returned
- Fix - Stop form hanging when scanner not supported
- Fix - UBC126AT Close Call Settings Error - UBC126AT has 6 band bits
not 5
Known Issues in V2.0.0.0. None
Version
|
File
|
MD5
Checksum
|
Date
|
V1.9.8.0 |
Scan125_V1980.zip |
4AD9E68FEF8B1F9C71F1B6A54A62EAE5
Scan125_V1980.zip
|
05 March 2017
|
V1.9.8.0 |
Scan125.exe
|
E3E068BBE69266EBB67601CA76BD25A3
Scan125.exe
|
05 March 2017 |
NEW in V1.9.8.0
- Add - Volume Control Slider and Mute function to Big and Ribbon
Displays (user request)
- Add - Download and Information buttons to the Program Update Check
(user request)
- Add - Replace "Buy Me A Coffee" with Charity Donation Request/Function
- new status of Careware/Charityware
Fixes in V1.9.8.0 Fix - Correct
Notepad field alignment when Autolog AE not set. Replace "AE" with
"--"
Known Issues in V1.9.8.0 Very
occasionally program gets confused by COM port issues and unkown model
issues
Version
|
File
|
MD5
Checksum
|
Date
|
V1.9.7.0 |
Scan125_V1970.zip |
D818147DD08658EDA4A6ADB17C0603EC
Scan125_V1970.zip
|
19 January 2017 |
V1.9.7.0 |
Scan125.exe
|
CAABDB3858DB7CE8F1B23EB73763782E
Scan125.exe
|
19 January 2017 |
NEW in V1.9.7.0
- Add - Automatic Temporary Lockout (TL/O) function (user request)
- Add - Signal strength (RSSI) to Notepad Log and Frequency Log Files
(after tone code) (user request)
- Add - Increase signal strength (RSSI) resolution from 5 to 10 step
values
- Add - Use "," not space and "," not ":" for Notepad Log and Frequency
Log Files - CSV support (user request)
- Add - Register Link Button to About Form
- Add - Use bolder font on About Form Product Name, Product Version,
etc. text to help with registration
- Add - Increase Autosaved Locations from 100 to 200
Fixes in V1.9.7.0
- Fix - About form mouse over pop-ups - Use Product and not Program
- Fix - Clearing of Copy Data array
- Fix - Ini file ini_mute_timer_warning_sound= not being correctly
loaded
Known Issues in V1.9.7.0 31Jan2017
- Notepad log field alignment error. When AE is not enabled it should
be replaced with -- and not a 'blank'
Version
|
File
|
MD5
Checksum
|
Date
|
V1.9.6.1 |
Scan125_V1961.zip |
A65BB0E828CEADEBB72B3B5B2502DEB6
Scan125_V1961.zip
|
04 September 2016 |
V1.9.6.1 |
Scan125.exe
|
EB34C86E92C73C0F139143748AB65BF1
Scan125.exe
|
04 September 2016 |
NEW in V1.9.6.1
Fixes in V1.9.6.1
- Fix - Correct CB channel to frequency conversion for EU (CEPT) and US
channels
- Fix - Correct Marine Channel upper channel number check (now 88
instead of 86)
- Fix - Correct air band frequency option override conflict with CB and
Marine frequencies
Known Issues in V1.9.6.1 None.
Version
|
File
|
MD5
Checksum
|
Date
|
V1.9.6.0 |
Scan125_V1960.zip |
7671F03BD4ECFB6AFCA04B834708F32B
Scan125_V1960.zip
|
03 September 2016 |
V1.9.6.0 |
Scan125.exe
|
61AD6049D37DDBB2D4802C2A0ECDD210
Scan125.exe
|
03 September 2016 |
NEW in V1.9.6.0
- New - Air Band Channel Frequency Conversion to Real 8.33 Step
Frequency - "ab" prefix (case insensitive)
- New - Air Band Channel Frequency Conversion Option Setting - no "ab"
prefix required
- New - UK CB Channel to Frequency Input Translation and Channel Tag
Name Input - "cbuk" prefix (case insensitive)
- New - EU/CEPT CB Channel to Frequency Input Translation and Channel
Tag Name Input - "cbeu" prefix (case insensitive)
- New - US/CEPT CB Channel to Frequency Input Translation and Channel
Tag Name Input - "cbus" prefix (case insensitive)
- New - CB Channel Default Region Option - "cb" prefix maps to "cbuk" or
"cbeu" or "cbus"
- Marine Channel to Frequency Input Translation and Channel Tag Name
Input - "ma" prefix (case insensitive)
- Marine Marina Channel to Frequency Input Translation and Channel Tag
Name Input - "m1"/"m2" prefix (case insensitive)
Fixes in V1.9.6.0
- Fix - Big Display minimum size values set to wrong values
Known Issues in V1.9.6.0
CB EU(CEPT) / US Frequency Conversion
Incorrect Marine Channel upper limit check
Airband frequency option conflict with CB and Marine channel functions
PLEASE
NOTE! I have had one report of this version of Scan125
locking-up on a PC with Windows 10 PRO. Version V1.9.5.0 had no such
issues on the same PC with Windows 10 HOME. IF YOU experience any
similar issues with Windows 10 PRO THEN PLEASE let me know. At the
moment I believe the issue is related a .NET issue which appears to be
resolved on Win 10 PRO by install MS .NET V4.6.2. Windows 10 HOME and
PRO ship with .NET V4.6.1 as standard. (info updated 25Aug2016)
Version
|
File
|
MD5
Checksum
|
Date
|
V1.9.5.0 |
Scan125_V1950.zip |
3F46A1BDF93C10E733F9ACC0ED6944B7
Scan125_V1950.zip
|
21 August 2016 |
V1.9.5.0 |
Scan125.exe
|
9ECA5F1A28B1E85E87A4C3F4B4F4C478
Scan125.exe
|
21 August 2016 |
NEW in V1.9.5.0
- New - Ribbon Display - with HOLD and HOLD release
- New - HOLD and HOLD release to Big Display (left mouse button)
- New - Increased granularity of Big Display and font sizing (up and
down)
- New - Ribbon Display and Big Display always "On Top" presence
- New - Form Main Control Panel Normal/Minimize/Normal function to
Ribbon and Big Displays (right mouse button)
- New - Remember Big and Ribbon Display Sizes and Positions
Fixes in V1.9.5.0
- Fix - Change of Big Display size/position not saved if main form is
closed before Big Display is closed
- Fix - Battery Meter Timer not being startedcom ports
Known Issues in V1.9.5.0 See PLEASE NOTE
above.
Version
|
File
|
MD5
Checksum
|
Date
|
V1.9.4.1 |
Scan125.exe
|
B4FD1EA4C9CF2D4248865CC09E66DE32
Scan125.exe
|
16 June 2016 |
Fixes in V1.9.4.1
Fix - Unable to store to a channel location with program saying location is
not empty, choose another location.
NOTE - Patch / Bug Release EXE files
*must* be installed into the Scan125 Current Release program
folder. If you are a new Scan125 user then you must
install the full Current Release
and then apply the Patch EXE. A
patch EXE file will not work on its own.
Version
|
File
|
MD5
Checksum
|
Date
|
V1.9.4.0 |
Scan125_V1940.zip |
C74F3D9E72AFA641082525AD3B2559B1
Scan125_V1940.zip
|
01 June 2016 |
V1.9.4.0 |
Scan125.exe
|
2571CA1888358842AB167F0BEF275313
Scan125.exe
|
01 June 2016 |
NEW in V1.9.4.0
Fixes in V1.9.4.0
- Fix - Scan Channels buttons Select B2 and Select B3 text and back
colours cross coded with B1
- Fix - Notepad Log Current not working - only works if autolog setting
is enabled
- Fix - Scanner does not process a blank/null tag name read from a
settings file. Pass space instead which scanner then turns to a
null/bank!
- Fix - Add additional 25% period delay when reading/doing band step
menu navigation to cater for slow PC com ports
- Fix - Clarify folder select in driver install text in User Manual
Version
|
File
|
MD5
Checksum
|
Date
|
V1.9.3.0 |
Scan125_V1930.zip |
88341DF19029BD8FC1F9DFCC975F0E7F
Scan125_V1930.zip
|
24 January 2016 |
V1.9.3.0 |
Scan125.exe
|
589B78F2CB4F96013E5AA46E12969806
Scan125.exe
|
24 January 2016 |
NEW in V1.9.3.0
- New - Automatic Scan, Search or Services Scans on program Start-Up
function
- New - Close Call Bank View & Store Support
Fixes in V1.9.3.0
- Fix - When in HOLD pressing HOLD button does not resume/release
- Fix - In Close Call Only Mode bank drop buttons should not be
operative
- Fix - If store pending is cancelled then any duplicate entry warning
is repeated
Version
|
File
|
MD5
Checksum
|
Date
|
V1.9.2.0 |
Scan125_V1920.zip |
8CB58669DA7971912EA51E6EF67B936A
Scan125_V1920.zip
|
05 December 2015 |
V1.9.2.0 |
Scan125.exe
|
DA149D02433780D50E036FBEB8CF7719
Scan125.exe
|
05 December 2015 |
NEW in V1.9.2.0
- New - Improved Text and Frequency FIND function with highlighing and
Find All support
- New - Improved STORE function with frequency and modulation
information and duplicate/existing data warning
- New - Improved Channel Printing Support - Bank 'n' and ALL Banks
- New - Optional Duplicate Frequency Entry Warning Message
- New - Cell Copy and Paste to/from the Scan Channels Datagrid View/Edit
Fixes in V1.9.2.0
- Fix - Don't enable main timer till all timer settings are read from
INI file
- Fix - Closing Scan Channels with STORE pending does not clear / reset
store process & buttons
Please Note: Versions listed
below are identical in function and source code. Repackaged on 26
October 2015.
Version
|
File
|
MD5
Checksum
|
Date
|
V1.9.1.1 |
Scan125.exe
|
4C293D354797AEB0C5764C006A7B99F7
Scan125.exe
|
26 October 2015 |
V1.9.1.1 |
Scan125.exe |
2DB4AA96EED9F212EB1C7BF356D3DD32
Scan125_V1911.exe |
21 September 2015
|
Sadly Windows 10 COM issues have thown another spanner in the works.
There is a Patch V1.9.1.1 available for download which hopefully resolves
issues where Windows 10 reports COM ports with trailing Chinese like
characters/symbols. V1.9.1.0 already resolves the Windows 10 issue of
trailing alpha/latin characters so you do not need the patch unless you have
the trailing Chinese like characters/symbols.
There is no new function in the V1.9.1.1 patch.
Please
Note: Versions listed below are identical in function and
source code. Repackaged on 26 October 2015.
Version
|
File
|
MD5
Checksum
|
Date
|
V1.9.1.0 |
Scan125_V1910.zip |
F6EEF67470C56C15CCD5895FBD7D1075
Scan125_V1910.zip
|
26 October 2015 |
V1.9.1.0 |
Scan125.exe
|
283288CB48A75C2120AB55F1017D242C
Scan125.exe
|
26 October 2015 |
V1.9.1.0 |
Scan125_V1910.zip |
525C822A5442D911865D59FE75F48EF8
Scan125_V1910.zip |
18 September 2015 |
V1.9.1.0 |
Scan125.exe |
9A07FE1CADF4AF5A8B193134B44AEA7A
Scan125.exe |
18 September 2015 |
NEW in V1.9.1.0
- New - SLOW Status Refresh Period Option Setting
- New - Additional FAST Status Refresh Period Option times
- New - Option to mute Status Timer Warning Sound
- New - Read actual scanner Band Step and Modulation settings
- New - Hit counter to Autosaved frequency log
- New - Frequency hit CSV log file
- New - Saving of Scan Channels/Banks in CSV format for data sharing
(Frequency, Modulation, Channel Tag Name)
- New - Option to change audio filename from frequency and modulation to
channel name tag, band name, service name
Fixes in V1.9.1.0
- Fix - System.NullReferenceException: Object reference not set to an
instance of an object - reception status returns null data in certain
circumstances
- Fix - Windows 10 lists COM/serial ports as COMn or sometimes COMni,
eg. COM3i
- Fix - Scanner Firmware Bug - Can not switch Band Plans via API -
removed this ability from Scan125
- Fix - Scanner Firmware Bug - Band Step sizes are Reset at Power On -
removed Band Step and Mod (BPS=) load and save functions from Scan125
- Fix - Scanner Firmware Bug - Band Modulations are Reset at/on Band
Plan switch - removed Band Step and Mod (BPS=) load and save functions
from Scan125
- Fix - Do not allow scanner status when Registration Dialogue is open
- Fix - Go into HOLD mode when registration required triggers
- Fix - Play Saved audio file open navigation menu not open up in
program's WAV directory
Version
|
File
|
MD5
Checksum
|
Date
|
V1.9.0.0 |
Scan125_V1900.zip |
2769D9D291BB84770D76855C54668F62
Scan125_V1900.zip
|
08 June 2015 |
V1.9.0.0 |
Scan125.exe
|
10AD4DB871FA1E43E6409C6490F26F87
Scan125.exe
|
08 June2015 |
NEW in V1.9.0.0
- New - Support for UBC126AT Scanner
- New - Logging of CTCSS and DCS tones used in a tranmission
- New - Allow major forms to "Snap To" borders/corners
Fixes in V1.9.0.0
- Fix - Data file load not allowed when in Standalone Mode and model us
"Unkown"
- Fix - Duplicate entries being lodded in autosave data between program
runs
- Fix - Suppress initial latency warning chime on program startup
Version
|
File
|
MD5
Checksum
|
Date
|
V1.8.0.0 |
Scan125_V1800.zip |
ABBA96FDC28B84A12CA3188AE33201E7
Scan125_V1800.zip
|
24 March 2015 |
V1.8.0.0 |
Scan125.exe
|
4D11B48B1CEB3AD6A3965982B72AA0FE
Scan125.exe
|
24 March
2015 |
NEW in V1.8.0.0
Fixes in V1.8.0.0
- Fix - Change scanner status polling to fix COM errors on Apple MAC PCs
Version
|
File
|
MD5
Checksum
|
Date
|
V1.7.0.0 |
Scan125_V1700.zip |
CAA1B200A887C62C8B8F6F97B2DD08A4
Scan125_V1700.zip
|
26 February 2015 |
V1.7.0.0 |
Scan125.exe
|
BFE6651D074874A08646ECF672F8DEE9
Scan125.exe
|
26 February 2015 |
NEW in V1.7.0.0
- New - Additional COM code (catch/try on setup, port open test &
reopen code, full command flush and retry)
- New - Virtual Big Scanner Display - can be resized up to full screen
- Change - Replace COM light with Port Text Box colouring (reduce
control overhead)
Fixes in V1.7.0.0
- Fix - Data exception with Global Lockout Frequency - indexing beyong
array end when full
- Fix - AScan Channels Find does not find frequency if decimal point is
present in search
Version
|
File
|
MD5
Checksum
|
Date
|
V1.6.0.0 |
Scan125_V1600.zip |
E8B4072D33F4532929166750D2C70D62
Scan125_V1600.zip
|
02 February 2015 |
V1.6.0.0 |
Scan125.exe
|
3156FADF77E64369026A7638AA7FFEB5
Scan125.exe
|
02 February 2015 |
NEW in V1.6.0.0
The following are new in Version 1.6.0.0
- Improve - Default model handling when no scanner attached
- Improve - Error Messaging
- Change - Channel Alpha Name invalid char action to replace with
*
Fixes in V1.6.0.0
- Fix - Data exception with Notepad & Auto-saved Frequencies
function
- Fix - Auto-saved Frequencies data grid not actively updating whilst
open/viewed
- Fix - Data cell edit Shift key and Space-bar terminates input with Row
Select
- Fix - Data entry error messages often shown with highlighted/selected
text
Version
|
File
|
MD5
Checksum
|
Date
|
V1.5.0.0 |
Scan125_V1500.zip |
EF7164774C245C5D9E58E050686D223F
Scan125_V1500.zip
|
03 January 2015 |
V1.5.0.0 |
Scan125.exe
|
4A4962A18DFF877891E00333CBCA4B4F
Scan125.exe
|
03 January 2015 |
NEW in V1.5.0.0
The following are new in Version 1.5.0.0
- Add DUAL Virtual Console Status intervals - FAST for scanning -
SLOW/default for idle
- COM port retry n times ability before invoking COM port error
- Separate all non COM port errors into different dialog report/action
Fixes in V1.5.0.0
- Fix - Sound recording not working for some users
- Fix - scan125-notepad.txt file path error
- Fix - Some user registration Key values not accepted by program
- Fix - Status Timer Interval only updated after program
shutdown/restart
- Fix - Not all Load/Save file dialogs defaulted to user's last used
location
Version
|
File
|
MD5
Checksum
|
Date
|
V1.4.0.0 |
Scan125_V1400.zip |
6475FEF563CBFE9E6868B3A6EF6E52F5
Scan125_V1400.zip
|
09 November 2014 |
V1.4.0.0 |
Scan125.exe
|
928C4AC17A330CA88E5FDF329E8A578C
Scan125.exe
|
09 November 2014 |
NEW in V1.4.0.0
The following are new in Version 1.4.0.0
- Add Audio Recording and Playback Functions with Auto Pause, Split and
Record options
- Add Battery Meter Splash time of 0 ms (to suppress meter display on
startup)
- Change Channel Alpha Name Tag edit action to truncate to 16 characters
instead of error dialogue
- Increase timer registration limit period from 5 minutes to 10 minutes
(5 minutes was a bit harsh)
Fixes in V1.4.0.0
None - nobody found/reported anything
Version
|
File
|
MD5
Checksum
|
Date
|
V1.3.0.0 |
Scan125_V1300.zip |
B2AB2FDA9EC8A46495B593D2743B4A18
Scan125_V1300.zip
|
27 September 2014
|
NEW in V1.3.0.0
The following are new in Version 1.3.0.0
- Add Notepad with additional Auto Logging
- Add Automatic Program Update Check (ships disabled)
Fixes in V1.3.0.0
Fix - Line count not updated when reading scanner data file - affects line 1
decoding
Fix - Do not reset scanner model on scanner full data file reload/read - use
last known model
Fix - Scan & Customer Search Bank Tag Names not cleared when Scanner is
reset.
Fix - Treat BUTEL file load as a #full# data file load
Fix - Disable scanner functions if model not supported
Fix - L/O lockout disrupts current scan due to uncessary Set & Get
Channel settings
Fix - Refresh Global Lockout Frequencies from scanner if attached
Fix - Correct/Add decode of Services scanning status for BC125AT scanner
Fix - Detect Scan Banks Scan actively running and inhibit Lockout action
Fix - Autoprev checkbox option always ticked
Windows 8 Driver Installation -
Windows 8 only allows the installation of signed drivers. For those
that tried to install the diver and failed then please try agian with the
new signed Uninden_Universal_Driver
which I up loaded today. The previous drivers have been withdraw
as they are no longer required. The User Manual has been updated with
new driver installation instructions.
The following bugs are known to exist and are in the process of being fixed
or are fixed in next release:
- Repeated use of "Load Scanner Settings" can result in an "Unhandle
exception has occurred". Namely
"System.IndexOutOfRangeException. Index was outside the bounds of
the array at FormMain.7DAA0(String ) andFormMain.6DAA0(Object .EventArgs
1AAAA)
This bug is fixed in the next release. I have only had one report of
this bug. If you have experienced this then please
let me know and if a number of you are hitting this problem then I will
issue and immediate patch.
If you do hit this bug then your scanner will still be loaded and functional
but you will have repeated Global Lockout Frequencies defined. The
workarounds for this are:
- Reset the scanner and "Load Scanner Settings" again
- Use to "Global Freq Lockouts View/Edit"
in the program and delete repeated entries
- On the scanner start a "Srch",
press "Hold", press and hold "L/O" to get "Confirm
Unlock All Frequncies?". Now press "E".
Version
|
File
|
MD5
Checksum
|
Date
|
V1.2.0.0 |
Scan125_V1200.zip |
F867595AD5D7BDC248036C99CDFEF336
Scan125_V1200.zip
|
07 August 2014
|
NEW in V1.2.0.0
The following are new in Version 1.2.0.0
- Add Volume On/Off Button
- Add Squelch On/Off Button
- Add Reset Defaults to Custom Search Form
- Add Tool tips/"Mouse Over" prompts to main menu bar
- Add COM Port Timeout record to ini file
- Improve data handling of full and partial file data loads
- Updated Help/User Manual
Fixes in V1.2.0.0
- Fix not writing channel number to saved data files if no scanner
attached a startup
- Fix occasional COM port timeout during normal use - timeout
increased from 5 seconds to 10 seconds
- Fix occasional COM port timeout during scanner reset - timeout
increased from 10 seconds to 30 seconds
- Fix Butel View/Edit cell data errors - store CTCSS as nnn.n frequency
and DCS as DCS code and don't use Uniden codes
- Fix Butel file load progress indicator not working
- Fix Butel bank number always being zero when importing a Butel file
- Note! The occasional COM port timeouts appear to be occurring when the
program is not the current foreground task.
It is hoped that increasing the normal timeout will resolve these
occasional timeouts.
Version
|
File
|
MD5
Checksum
|
Date
|
V1.1.0.2 |
scan125_V1102.exe |
1284CD1F3F3CD386E0C063E07023F6F9
Scan125_V1102.exe
|
09 June 2014 |
This patch includes patch V1.1.01 (see previous
release history)
This patch corrects an issue with converting "nnnn.nnnn" frequency to type
single.
************** Exception Text **************
System.InvalidCastException: Conversion from string "0000.0000" to
type 'Single' is not correct. ---> System.FormatException: Input
string was not in a correct format.
You may see/have this error if your Windows PC is using a National Language
Local (other than en-GB or en-US)
where the "," (comma) is used as the
decimal place separator as opposed the "."
(decimal point/period).
If you have these issues then please download the scan125_V1102.exe file
that you will also find in the download directory. Rename your
existing scan125.exe file to scan125_V110n.exe and then copy the
scan125_V1102.exe to your program installation location and rename it to
scan125.exe
Version
|
File
|
MD5
Checksum
|
Date
|
V1.1.0.1 |
scan125_V1101.exe |
EEADCEE2886DBD1AEB86F83FFD2CBBF5
Scan125_V1101.exe
|
05 June 2014
|
Despite loads of testing for release V1.1.0.0 some issues/bugs slipped
through which I feel I should immediately correct. These are:
- BC125AT only - Service scan FRS...
and Racing check boxs misbehaving - check boxes get cross
connected /confused
- Set default file_directory to ".\"
- This will only affect new users who do not have an exiting normal user
directory for loading and saving files. These users will find that
they get an error when closing the program as the program tries to
write PREVlast data to the root directory. If you don't want to
install this patch all you have to do is save/load a scanner data file
and doing this will set your default directory path.
- Correct additional registration
issues with user KEYs containing '0's
- Web Version Update Check Being Cached
- the web update check often loads a chached version from the last
check. This often means that you are told your program is
up-to-date when it is not
If you have these issues then please download the scan125_V1101.exe file
that you will also find in the download directory. Rename your
existing scan125.exe file to scan125_V1100.exe and then copy the
scan125_V1101.exe to your program installation location and rename it to
scan125.exe
If you are installing Scan125 for the
first time then please fully install V1.1.0.0 and then apply the V1.1.0.1
patch.
There are no functional or feature differences between V1.1.0.0 and V1.1.0.1
This information is provided for your verification of past official
releases.
Version
|
File
|
MD5
Checksum
|
Date
|
V1.0.0.1 |
scan125_V1001.exe |
F8B9A349D345EF27D6E1124B555EF388
Scan125_V1001.exe |
17 May 2014
|
If you wish to use Scan125 on a Windows installation configured with some
non UK / US date formats then you may see this error:
If you have this problem then please download the scan125_V1001.exe file
that you will also find in the download directory. Rename your
existing scan125.exe file to scan125_V1000.exe and then copy the
scan125_V1001.exe to your program installation location and rename it to
scan125.exe
If you are installing Scan125 for the first time then please fully install
V1.0.0.0 and only apply the V1.0.0.1 patch if you have this problem.
There are no functional or feature differences between V1.0.0.0 and V1.0.0.1
Version
|
File
|
MD5
Checksum
|
Date
|
V1.0.0.0 |
Scan125_V1.0.0.0.zip |
8A0C45003B1B2FF7D473FBE6E04B9772
Scan125.zip |
29 April 2014
|
Contact Information
If you want or need to contact me about this program then please Email:
scan125
|
@
|
nick-bailey
|
.
|
co
|
.
|
uk
|
Top Of Page
© Nick Bailey 2013-2023